Model-specific reset guide
Canon TR4522 Ink Absorber Full Reset
The waste ink system in Canon TR4522 collects ink used during cleaning cycles. Once the estimated limit is reached, service mode and a compatible counter reset may be required.
Why Canon TR4522 reports an absorber error
Cleaning operations send unused ink into absorber pads inside the printer. Canon TR4522 estimates their usage with an electronic counter and can lock printing when that value reaches its limit.
Wic Reset Connect is designed to reset the compatible counter in Canon TR4522. The physical waste ink system should still be inspected and maintained when necessary.
How to enter service mode on Canon TR4522
- Turn the printer off.
- 按住 停止/重置.
- 在按住停止/复位的同时,按住 电源.
- Release Stop/Reset but keep holding Power.
- Press and release Stop/Reset 5次.
- Wait briefly, then release Power. The power indicator should remain steadily lit.
Reset the counter in Canon TR4522
Check cartridges, close Canon utilities and connect the printer directly to Windows before beginning the reset.
-
Prepare the printer
Resolve other errors, confirm a steady power light and enter service mode using the sequence above.
-
Connect directly by USB
Connect Canon TR4522 to a Windows 7, 8, 10 or 11 computer without Wi-Fi or a USB hub.
-
Start Wic Reset Connect
Run the program as Administrator and wait until the Canon service-mode device is detected.
-
Enter the key and reset
Enter the purchased key, select Reset and keep the printer connected until confirmation appears.
If Canon TR4522 is not detected
- If Windows does not detect a service-mode device, restart the printer normally, wait 10 seconds and repeat the preparation.
- If the power light blinks, resolve the displayed cartridge, paper or mechanical error before trying service mode again.
- Connect Canon TR4522 directly to the computer and try another data-capable USB cable or port.
- Run Wic Reset Connect as Administrator and keep internet access active for key validation.
Canon TR4522 reset FAQ
应该按多少次停止/复位键?
For Canon TR4522, use 5 Stop/Reset presses in the sequence shown on this page.
Does the reset clean the ink absorber?
No. It resets the stored counter. Inspect, clean or replace the absorber pads when their physical condition requires maintenance.
Does Canon TR4522 require service mode?
Yes. The printer must expose its maintenance interface before the counter can be reset with Wic Reset Connect.
Restore Canon TR4522